Low-Intensity Pulsed Ultrasound for Treatment of Fractures and Nonunions - Current Evidence and Insights from Basic Research and Clinical Application

Z Orthop Unfall.,
Randau TM, Kabir K, Gravius S, Wimmer MD, Friedrich MJ, Burger C, Goost H

In Germany, 800,000 fractures are treated per year, and up to 10 % of these patients may suffer subsequently from a delayed union or a nonunion at the fracture site. Surgical treatment of these complications is tedious and associated with high costs. Therefore non-operative treatment is recently receiving more scientific and clinical attention. The adjuvant treatment with ultrasound has been propagated for the past years to enhance fracture healing and bony union, and has been discussed controversially. This review article demonstrates the significance of the low intensity pulsed ultrasound application in fracture treatment, on the basis of basic science results, animal experiments and the results of clinical trials.

Full article available at PubMed.gov.

Low-intensity pulsed ultrasound in the treatment of nonunions.

The Journal of Trauma,
Nolte PA, van der Krans A, Patka P, Janssen IM, Ryaby JP, Albers GH

Questo studio ha rivelato che EXOGEN può essere utile nel trattamento di mancati consolidamenti accertati, di difficile trattamento, con un tasso di guarigione complessivo dell'86%.

Articolo intero disponibile sul sito PubMed.gov.

Low-intensity pulsed ultrasound: effects on nonunions.

Ultrasound in Medicine and Biology,
Gebauer D, Mayr E, Orthner E, Ryaby JP

In questo studio, 67 fratture con mancato consolidamento sono state trattate con EXOGEN. Dopo trattamenti giornalieri di 20 minuti, l'85% dei casi di mancato consolidamento risultava guarito.

Articolo intero disponibile sul sito PubMed.gov.

Improved healing response in delayed unions of the tibia with low-intensity pulsed ultrasound: results of a randomized sham-controlled trial.

BMC Musculoskeletal Disorders,
Schofer MD, Block JE, Aigner J, Schmelz A

Nel primo studio di livello I riguardante i tassi di guarigione dei mancati consolidamenti, 51 pazienti con consolidamenti ritardati della tibia sono stati trattati con EXOGEN. Il miglioramento medio nella densità minerale ossea è risultato 1,34 maggiore rispetto a quello osservato nei pazienti trattati con un dispositivo placebo.

Articolo intero disponibile per il pobrania o sul sito PubMed.gov.

Acceleration of tibia and distal radius fracture healing in patients who smoke.

Clinical Orthopaedics and Related Research,
Cook SD, Ryaby JP, McCabe J, Frey JJ, Heckman JD, Kristiansen TK

Questo studio rivela che i fumatori con fratture della tibia e del radio comprese nelle indicazioni* guariscono più rapidamente quando utilizzano EXOGEN (velocità maggiore del 41% per le fratture della tibia e del 51% per le fratture della parte distale del radio).

Articolo intero disponibile sul sito PubMed.gov.

Acceleration of tibial fracture-healing by non-invasive, low-intensity pulsed ultrasound.

The Journal of Bone and Joint Surgery,
Heckman JD, Ryaby JP, McCabe J, Frey JJ, Kilcoyne RF

Questo studio dimostra l'efficacia del sistema di guarigione ossea EXOGEN. È stato riscontrato che il tempo di guarigione delle fratture recenti* era significativamente ridotto quando EXOGEN veniva applicato per 20 minuti al giorno, con un tasso di guarigione pari al 94% dopo 150 giorni per il gruppo trattato con EXOGEN.

Articolo intero disponibile sul sito PubMed.gov.

Accelerated healing of distal radial fractures with the use of specific, low-intensity ultrasound. A multicenter, prospective, randomized, double-blind, placebo-controlled study.

The Journal of Bone and Joint Surgery,
Kristiansen TK, Ryaby JP, McCabe J, Frey JJ, Roe LR

In questo studiox 60 pazienti con fratture recenti del radio hanno utilizzato EXOGEN o un dispositivo placebo per un periodo di 10 settimane. I pazienti che hanno utilizzato EXOGEN hanno presentato un tempo di consolidamento significativamente più breve, dimostrando una maggiore velocità in ogni fase del processo di guarigione.

Articolo intero disponibile sul sito PubMed.gov.

Indications and results for the EXOGEN ultrasound system in the management of non-union: a 59-case pilot study.

Orthopaedics, Traumatology, Surgery & Research (OTSR),
Roussignol X, Currey C, Duparc F, Dujardin F.

This pilot series sought to assess the use of EXOGEN in the treatment of femoral or tibial non-unions. The 88% bone healing rate, which is higher than in traditional surgery and with a unit cost at least 60% lower, supports advocating first-line implementation in non-unions of less than 10mm with stable osteosynthesis.

Abstract available at PubMed.gov.

  • Elevata adesione
    al trattamento21
  • +
  • Efficacia clinica
    dimostrata2-4
  • > >
  • Risultati positivi nella
    guarigione delle fratture